CW-5000 industrial Water Chiller Cooler for Cooling CO2 Glass Laser Tube Under 80W/100W of the Laser Engraving Tool
$1515
Plug 220V EU Plug/Plug 110V US Plug/
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Description
CW-5000 Series are professional cooling machines referring to international, advanced thermolysis cooling system designed, suitable for small water-cooled cooling devices requested machinery. The Industrial Water Chiller has a patent Certificate, CE and RoHS Certificate.
It is designed for cooling the one CO2 glass laser tube under 80W/100W of the laser engraving and cutting machine. Emmiting rate higher than 60%.
Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling parameters.
It will self-adjust controlling parameters according to room temperature to meet cooling demands.
Application
Mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted.
Economic cooling equipment, easy to install and operate, compact and easily movable.
Our industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature. With this 1 key solution, customers no longer need to worry about water temperature adjustment of seasonal changes.
How to use
Fill the water tank with purified water.
Connect the water inlet of the water tank to the water outlet of the laser machine and connect the water outlet of the water tank to the water inlet of the laser machine.
Installation steps
A. Open the package to check if the machine is intact and all the necessary accessories are completed.
B. Open the injection port to feed cooling water.
Observe water level gauge while adding water slowly, be careful not to have water overflowed! For the cooling of carbon steel equipment, water should be added with an appropriate amount of anti-corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid.
C. According to system conditions, please well connect water inlet and outlet pipe.
D. Plug in, turn on the power switch. (Do not start up without water in the tank!)
(1) Circulation pump of the chiller starts working. Operating for the first time may produce bubbles in the pipe, which occasionally leads to flow alarming. In such case, it will go back to normal after running for a few minutes.
(2) After the first boot, please immediately check whether the water pipe leaks.
(3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.
(4) As it takes a longer time to start the compressor and other components, the time you take might range from seconds to minutes, please do not turn the power off and on again frequently.
E. Check the water level in the water tank.
The first startup of the new chiller empties the air in the water pipe, leading slightly water level decline. In order to keep the water level in the green area, it’s allowed to replenish adequate water. Please observe and record the current water level and inspect it again after the chiller has been running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.
F. Adjust parameters of temperature controller.
CW-5000 series use an intelligent thermostat. Normally users do not need to adjust it. If it’s really necessary, please refer to ‘Operating status and parameters adjustment.’
Notice
Cooling water must be kept empty when cooling machine has been not in use for long or in transport.
It is strictly forbidden to plug and run the cooler without feeding water.
Cooler should be placed in a well-ventilated, dry environment away from heat sources. Please keep at least 30cm from obstructions to the air outlet which is in the back of the cooler, and leave at least 10cm between obstructions and air inlets of two sides.
To protect laser tubes , the radiator fan of cooler will suspend to work when water temperature is too low , and it will restart to run when water temperature rises back to acceptable range.
To ensure good heat dissipating, please open the lid to clean the dirt regularly.
Working in cold north area, it is better to use noncorrosive antifreeze fluid.
Alarm Function
E1- Over high room temperature
E2- Over high water temperature
E3- Over low water temperature
E4- Room temperature sensor failure
E5- Water temperature sensor failure
Remark
When alarm occurs, the error code and the temperature will be alternately displayed.
In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated.
Flow alarm and output ports
In order to guarantee that the equipment will not be damaged when cooling water circulation is out of control, CW-5000series chillers possesses an unique low flow alarm protection.
The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.
Features
6L cooling tank capacity
Energy saving, long working life and simple operation
Different models according to local voltage and frequency
With completed water flow and over high temperature alarm functions
Professional forced air-cooled radiator, high heat dissipating capacity and not easy to be blocked
Equipped with alarm output port, can quickly protect sensitive components
Multiple power specifications; CE approval; RoHS approval
Water is available for a long time use
Real-time temperature monitoring, accurate knowledge of heating devices working condition
High cost performance, low failure rate
800W cooling capacity; optional environmental refrigerant ±0.3°C precisely temperature control
The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions
Multiple alarm functions:compressor time-delay protection, compressor overcurrentprotection, water flow alarm and over high / low temperature alarm
Optional heater and water filter
Specification
Model:CW-5000DG
Voltage:220V
Frequence:60HZ
Current:3.5~5.6A
Tank Capacity:6L
Compressor Power:0.305KW, 0.41HP
Refrigerating Capacity:2866Btu/h, 0.84KW, 722Kcal/h
Refrigerant:R-134a
Refrigerant Charge:280g
Precision:±0.3℃
Reducer:Capillary
Pump Power:0.03KW
Maximum Flow:10L/min
Maximum Pumping Lift:8M
Inlet and Outlet:External Φ10mm brass connector
Packing Dimensions:720*440*620mm (L*W*H)
Protection:Over current protection for compressor, flow alarm, over temperature alarm
Package included
1 x CW-5000DG Water Chiller Machine
1 x Power Cable
1 x Connection Hose
2 x Sealing Washer
1 x Spare Fuse
1 x User Manual
1 x Alarm Signal Output Plug
Weight | 27 kg |
---|
Only logged in customers who have purchased this product may leave a review.
Customers Also Viewed
-
TOOLTOP ET89UK Socket Tester Digital Big Display Current Voltage Frequency Meter Ground Zero Line UK Plug Polarity Phase Check
$19Socket TesterAdd to cartFeaturesIntelligent detection to ensure the safety of household electricity.RCD test, one-key detection of leakage protector status.As a general measurement tool and widely used in the school, laboratory, factory and other social field.Lightweight and handy size, easy to carry and storage.With three indicators and LCD screen, it is easy for a newer to use it.The program …