SodaStream Cylinder Refill Adapter + Bleed Valve + W21.8-14 /US CGA320 Connector
$46
Size 1#/Size 2#/Size 3#/
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard
Description
SodaStream Cylinder Refill Adapter + Bleed Valve + W21.8-14 /US CGA320 Connector
Specification
Material:Brass
1:US/CA Version:TR21-4(Sodastream Cylinder)to CGA320
2:EU Version:TR21-4(Sodastream Cylinder)to W21.8-14
3:AU/NZ Version:G1/2(Sodastream Cylinder)to W21.8-14
Features
This adaptor for sodastream cylinder will enable you to fill your own CO2 from your larger bulk cylinder into smaller soda cylinders. An easy and inexpensive way to fill your own soda cylinders at home at a fraction of the cost of getting the refills from your local store.
Can be used with large co2 tanks with CGA320 connector(USA, CAN, Brazil, Colombia, Philippines…) or DIN477 / W21.8-14(right hand) Connector / JIS m22-14 Valve of CO2 Tank (KOR, JP, UK, Germany, France, Poland, Norway, Switzerland, Russia, Ukraine, South Africa, Sweden, Chile, Czech Republic, Singapore,Australia,New Zeland…)
Uasge
1. Screw the adapter to a commercial CO2 gas cylinder
2. The empty CO2 cylinder is screwed into the adapter
3. Open the valve of the large gas bottle
4. After about 15-20 sec., The cylinder is completely filled
5. Close valve of the large gas bottle
6. Opening the bleed screw to drain residue remaining gas
7. Unscrew the CO2 cartridge – done
When using, be sure to following these important points
1. That the seals goes in the correct location. So when the soda filling adaptor arrives, please make sure to use the correct seal in the correct side.
2. Make sure to put the soda cylinder on the correct side. The soda cylinder thread can actually fit both sides of this adaptor, but the CO2 cylinder only fit’s into the ROUND SIDE. As a result you MUST put the soda cylinder into the HEXAGONAL SIDE. (as show in image)
Information of Filling the newer Co2 cylinder with filling protection valve(6mm wide valve pin)
Unlike the other cylinder valves, this valve must be filled with a slow increase in pressure.
When refilling, it is important that the pressure in the first few seconds is very low, only the cylinder valve remains open. The handwheel is therefore open at the beginning only slightly and very slowly until some gas flows through (this can heard). Wait about 10 seconds and then turn the hand wheel slowly by hand half a turn further on. After another 10 seconds, the hand wheel can be turned all the way. Wait about 30 seconds until you hear no gas flows and turn the handwheel to back. After, filling is complete.
Since the handwheels opens the handwheel slightly, it is advantageous, for example, on the first attempt. Carefully turn with a small pipe wrench piece. Due to the larger lever, the flow can be controlled . After a few attempts it will come off by hand -without aid. If there is gas flow during the untwisting at the beginning… stop!! You must repeat the filling operation. The adapter must be vented in advance.
The cylinder should be empty. Pre Cooled cartridges will get quite full
Package Included
1 x Adapter
1 x Bleed Valve
1 x W21.8-14 or CGA320 Connector
Weight | 0.187 kg |
---|
Only logged in customers who have purchased this product may leave a review.
Customers Also Viewed
-
TOOLTOP ET89UK Socket Tester Digital Big Display Current Voltage Frequency Meter Ground Zero Line UK Plug Polarity Phase Check
$19Socket TesterAdd to cartFeaturesIntelligent detection to ensure the safety of household electricity.RCD test, one-key detection of leakage protector status.As a general measurement tool and widely used in the school, laboratory, factory and other social field.Lightweight and handy size, easy to carry and storage.With three indicators and LCD screen, it is easy for a newer to use it.The program …
Reviews
There are no reviews yet.