Warning: Undefined variable $main_header_opt in /www/wwwroot/gkvu.com/wp-content/themes/open-shop-child/inc/header-function.php on line 276
Call To +18 Email : Info

TFC-1000L Frequency Meter 8 High Brightness LED Display Frequency Ranges 10Hz ~ 1 GHz Frequency Counter

SKU: GKVU-1616122

$180

Dispatch:Usually will be shipped in 24 hours
Shipping:Standard Shipping about 10-25 business days
Secure Payment:Paypal,VISA,MasterCard

Features
Novel style, lightweight.
Cycle cumulative measurement.
Both importations frequency ranges:10Hz to 1 GHz
Highest input sensitivity:20mVrms.
8 high brightness LED display windows, 0 to 9 characters display simultaneously in cycle a self-test function.
Stability:±3*10-9s
Specifications
1. Measurement methods
(1) Frequency measurement
A channel
Range:10Hz-10MHz (Direct count)
10MHz-100MHz (proportion count)
Direct count:1Hz ,10Hz,100Hz(your choice)
proportion count:10Hz ,100Hz,1000Hz(choice)
Strobe time:0.01s,0.1s,1s (your choice)
Accuracy:±count value± base time error *measured frequency
B channel
Range:100MHz-1GHz
Resolution:100Hz,1KHz,10KHz
Strobe time:0.01s,0.1s,1s
Strobe time:0.01s,0.1s,1s
period measurement
Input:A channel
Range:10Hz-10MHz
Resolution:10-7s, 10 -8s, 10 -9s (your choice)
Accuracy:±count value± base time error *measured frequency
(3)accumulate measurement
Input:A channel
Range:10Hz-10MHz
Accuracy:±1 count impulse
Self-check
Monitor:0-9 characters of 8 digital pipe repeatedly shows
2. Input characteristics
(1)A channel
Input sensitivity:(10MHz) range:10Hz-8MHz 20mVrms
8MHz-10MHz 30mVrms
(100MHz) range:10MHz-8MHz 20mVrms
80MHz-100MHz 30mVrms
Attenuation:*1, *20 fixed
Wave filtering:low pass, 100KHz,-3dB
Impedance:about 1 MΩ (
Max. Safety voltage:250V (DC+AC rms)
(2)B channel
Input sensitivity:20mVrms
Impedance:about 50 Ω
Max. Safety voltage:3V
3. Time base
Time base frequency:10MHz
Short-term stability:±3*10-9/s
Long –term stability:±2*10-5/s
Temperature Coefficient:±1*10-5, 00C-400C
Line voltage:Each change ± 10%, the frequency variation ± 1 x 10-7 correspond
4. Power supply voltage:AC220± 10% 50Hz
5. Start time:20 minutes (
6. Temperature:working temperature -50C-500C
Storage and transportation temperature:-400C-600C
7.Humidity:Working Humidity:10-90% RH
Storage Humidity:5-95% RH
8. Dimension:230*200*75 mm
9.Weight:2Kg
Package Includes