Product adopts industrial-grade chip, high-precision SHT20 temperature and humidity sensor.
Product Function
Product features are two main types of classification:the functions of temperature and humidity;
Function of temperature are as follows
1. The automatic identification of work mode
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode ‘C’.
Start temperature
2. Cooling mode
When the temperature ≥ Start temperature, relay conduction, red led on, refrigeration equipment begin to work;
When the temperature ≤ Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;
3. Heating mode
When the temperature ≤ Start temperature, relay conduction, red led on, heating equipment begin to work;
When the temperature ≥ Stop temperature, relay disconnect, red led off, heating equipment stop to work;
4. Temperature correction function OFE (-10.0 ~ 10℃)
The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;
How to set the start/stop temperature
1. In the running interface, Long Press ‘ TM+ ‘ key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM- key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ‘ TM-‘ key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM- key, to be modified after the parameters, waiting for 6s automatic exit and save;
The humidity function is as follows
1. The automatic identification of work mode
The system automatically according to the start/stop humidity, identify work mode;
Start humidity> stop humidity, dehumidification mode ‘D’.
Start humidity
2. Dehumidification mode
When the humidity≥ Start humidity, relay conduction, green led on, dehumidification equipment begin to work;
When the humidity≤ Stop humidity, relay disconnect, green led off, dehumidification equipment stop to work;
3. Humidification mode
When the humidity≤ Start humidity, relay conduction, green led on, humidification equipment begin to work;
When the humidity≥ Stop humidity, relay disconnect, green led off, humidification equipment stop to work;
4. Humidification correction function RH (-10.0 ~ 10%)
The system is working for a long time and may be biased, through this function correction, the actual humidity = measuring humidity + calibration value;
How to set the start/stop humidity
1. In the running interface, Long Press ‘ RH+ ‘ key more than 3 seconds, into the start humidity settings interface, can be modified by RH + RH – key, to be modified, waiting for 6s automatic exit and save;
2. In the running interface, Long Press ‘ RH-‘ key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;
Running Interface Description
Working mode shows that the current mode (inchH/Cinch, inchE/dinch) will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed.
Any relay conduction, the upper-left corner of the interface display inchoutinch, if the temperature relay conduction, the flashing display temperature working mode inchH/Cinch to show reminders; if the humidity relay conduction, then flashing display humidity working mode inchE/dinch, as a reminder;
Other features
1. Parameter remote read/set
Through the UART, set the starting temperature/humidity, stop temperature/humidity, temperature/humidity correction parameters;
2. temperature/Humidity Real-time reporting
If the temperature/humidity reporting function is turned on, the product will detect the temperature/humidity and relay status by the 1s interval, and pass the UART to the terminal to facilitate data collection;
3. Relay enabling (by default)
If the relay is disable, the relay remains disconnected;
How to modify the temperature/humidity correction value
1. 1. In the operating interface, double-click the ‘ TM+ ‘ key to enter the correction of the set interface, the downward display correction of the type, the upward display of specific values; (OFE:Temperature correction value RH:Humidity correction value)
2. At this time by a short press ‘ TM-‘ key, switch to modify the parameters, through the RH+ RH-key, modify the specific value of the support long press short;
3. When the parameters have been modified, double-click the ‘ TM+ ‘ key, exit the correction positive setting interface, and save the data;
How to enable/disable relay
In the running interface, Short press ‘ TM-‘ key, enable/disable the temperature relay(ON:enable OFF:disable), back to the running interface, if the temperature relay is disable, the temperature symbol ‘ ℃ ‘ flashes to remind.
In the running interface, Short press ‘ RH-‘ key, enable/disable the humidity relay (ON:enable OFF:disable), back to the running interface, if the humidity relay is disable, the humidity symbol ‘% ‘ flashes, as a reminder.
Serial control(TTL level)
Baud Rate:9600bps Data bits:8
stop bits:1
crc:none
Flow control:none
CMD:Description
start:start data upload
stop:stop data upload
read:Read the param setting
T:ON:Temperature relay enable
T:OFF:Temperature relay disable
H:ON:Humidity relay enable
H:OFF:Humidity relay disable
TS:XX.X:Set start Temperature
(-20.0~60.0)
TP:XX.X:Set stop Temperature
(-20.0~60.0)
HS:XX.X:Set start Humidity
(00.0~100.0)
HP:XX.X:Set stop Humidity
(00.0~100.0)
TC:XX.X:Set Temperature Calibration
(-10.0~10.0)
HC:XX.X:Set Humidity Calibration
(-10.0~10.0)
Temperature and humidity Data upload format Description
Temperature format:Operating mode (H/C), temperature value, temperature relay status;
Humidity Format:Operating mode (E/D), humidity value, humidity relay status;
H,20.5℃,CL:Heating operating mode, the current temperature of 20.5 degrees, temperature relay disconnection state;
D,50.4%,OP:Dehumidification working mode, current humidity 50.4%, humidity relay connection;
Package includes
1 X XY-WTH1 Controller
Details pictures:
Weight | 0.095 kg |
---|
Only logged in customers who have purchased this product may leave a review.
Customers Also Viewed
-
TOOLTOP ET89UK Socket Tester Digital Big Display Current Voltage Frequency Meter Ground Zero Line UK Plug Polarity Phase Check
$19Socket TesterAdd to cartFeaturesIntelligent detection to ensure the safety of household electricity.RCD test, one-key detection of leakage protector status.As a general measurement tool and widely used in the school, laboratory, factory and other social field.Lightweight and handy size, easy to carry and storage.With three indicators and LCD screen, it is easy for a newer to use it.The program …
Reviews
There are no reviews yet.