DSO4000C Series
2 Channel Digital Oscilloscope + Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger.
The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously.
Large and clear display (7 inch 64K color LCD display, Resolution 800×480), more clear and realistic waveform.
Oscilloscope:1GSa/s Sample Rate, 200/100/70MHz Bandwidth, more than 20 kinds of auto measurement functions.
Powerful Trigger Function:Edge, Video, Pulse, Slope, Over time, Alternative.
Arbitrary/Function Waveform Generator:25MHz, 12 bits resolution, 200MHz DDS, Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer.
Support SD card, VGA function (optional).
Integrated USB Host, Support USB disk storage, USB interface/SD card system update.
Features
100MHz Bandwidth; 1GSa/s Sample Rate.
2 Channel Oscilloscope; 40 Kilo Byte(KB) Record Length.
7 inch 64K color LCD display, Resolution 800×480.
32 kinds of Automotive measurement, with FFT function.
25MHz Arbitrary waveform output (Sine wave up to 75MHz).
Powerful trigger function:Video, Edge, Pluse Width, Slope, Overtime, Alternate Trigger.
Specification
Oscilloscope:DSO4102C
Sample Rate:Sampling Rate Range:1GSa/s
Equivalent Sample Rate:25GSa/s
Acquisition Modes
Normal:Normal data only
Peak Detect:High-frequency and randon glith capture
Average:Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling:AC, DC, GND
Inpits Impendance:1M2% 20pF3pF
Probe Attenuation:1X, 10X
Supported Probe Attenuation Factor:1X, 10X, 100X, 1000X
Maximum Input Voltage:CAT I and CAT II:300VRMS (10*)
CAT III:150VRMS(1*);
Installation Category II:derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal
Sample Rate Range:1GS/s
Waveform Interpolation:(sin x)/x
Record Length:40 Kilo Byte(KB)
SEC/DIV Range:4ns/div to 40s/div
Sample Rate and:50ppm at over any 1ms time interval)
Delay Time Accuracy
Position Range:20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Δ Time Measurement Accuracy
(Full Bandwidth):Single-shot, Normal mode:(1 sample interval +100ppm * reading + 0.6ns);
>16 averages:(1 sample interval + 100ppm * reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution:8-bit resolution, all channel sampled simultaneously
Position Range:2mV/div to 10V/div
Bandwidth:100MHz
Rise Time at BNC( typical):3.5ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled:500mV/div to 2V/div, 40V; 5V/div, 50V
Math:+, -, *, /, FFT
FFT:Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit:20MHz
Low Frequency Response (-3db):10Hz at BNC
DC Gain Accuracy:4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode:When vertical displacement is zero, and N 16:(3% * reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and N16:[3% * (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, Average Acquisition Mode:Δ volts between any two averages of 16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types:Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source:CH1, CH2, EXT, EXT/5, AC Line
Coupling Type:DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type):DC(CH1,CH2)
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DCEXT)
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DCEXT/5)
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
AC:Attenuates signals below 10Hz;
HF Reject:Attenuates signals above 80kHz;
LF Reject:Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range:CH1/CH2:8 divisions from center of screen;
EXT:1.2V;
EXT/5:6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times 20ns:CH1/CH2:0.2div * volts/div within 4 divisions from center of screen;
EXT:(6% of setting + 40mV);
EXT/5:(6% of setting + 200mV);
Set Level to 50%(typical):Operates with input signals 50Hz
Video Trigger
Video Trigger Type:CH1, CH2:Peak-to-peak amplitude of 2 divisions;
EXT:400mV;
EXT/5:2V
Signal Formats and Field Rates, Video Trigger Type:Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range:100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode:Trigger when (
, = , or ); Positive pulse or Negative pulse
Pulse Width Trigger Point:Equal:The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal:If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than:The trigger point is the trailing edge.
Greater than (also called overtime trigger):The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range:20ns ~ 10s
Slope Trigger
Slope Trigger Mode:Trigger when (
, = , or ); Positive slope or Negative slope
Slope Trigger Point:Equal:The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal:The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than:The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than:The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range:20ns ~ 10s
Overtime Trigger
Over Time Mode:Rising edge or Falling edge
Time Range:20ns ~ 10s
Alternative Trigger
Trigger on CH1:Internal Trigger:Edge, Pulse Width, Video, Slope
Trigger on CH2:Internal Trigger:Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution:6 digits
Accuracy (typical):30ppm (including all frequency reference errors and 1 count errors)
Frequency Range:AC coupled, from 4Hz minimum to rated bandwidth
Signal Source:Pulse Width or Edge Trigger modes:all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode:The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to
Edge Trigger mode:The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode:The Frequency Counter does not work.
Measure
Cursor Measurement:Voltage difference between cursors:V
Time difference between cursors:T
Reciprocal of T in Hertz (1/T)
Auto Measuerment:Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,
+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid,
Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH,
FRF, FFR, LRR, LRF, LFR, LFF
Signal Source Mode
Waveform Impedance:DC-25MHz
Sample Rate:200MHzDDS
Output Waveform:Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC
Frequency Resolution:0.1%
Waveform Depth:4KSa
Vertical Resolution:12bit
Frequency Stability
Waveform Range:3.5V Max
Output Impedance:50
Output Current:50mA Ipeak=100mA
System BW:25M
Harmonic Distortion:-50dBc 1KHz -40dBc 10KHz
General Features
Display
Display Type:7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution:800 horizontal by 480 vertical pixels
Display Contrast:Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical):About 5Vpp into 1M load
Frequency(typical):1kHz
Power Supply
Supply Voltage:100-120VACRMS(10%), 45Hz to 440Hz, CAt II
120-240VACRMS(10%), 45Hz to 66Hz, CATII
Power Consumption
Fuse:2A, T rating, 250V
Environmental
Temperature:Operating:32 to 122 (0 to 50);
Nonoperating:-40 to 159.8(-40 to +71)
Cooling Method:Convection
Humidity:+104 or below (+40 or below):90% relative humidity;
106to 122(+41 to 50):60% relative humidity
Altitude:Operating:Below 3,000m (10,000 feet);
Nonoperaring:Below 15,000m(50,000 feet)
Mechanical
Size:Length 385mm, Width 200mm, Height 245mm
Weight:3.5KG(with Packing); 2.08KG(without Packing
Package includeds
1 x Hantek DSO4102C Handheld Digital Multimeter Oscilloscope
2 x Passive Probe
1 x Alligator Clip Cable
1 x USB Cable
1 x CD
1 x User Manual
,
Weight | 3.506 kg |
---|
Only logged in customers who have purchased this product may leave a review.
Customers Also Viewed
-
Punch Plier Leather Belt Round Hole Punch Eyelet Strap Revolving DIY Tool Heavy Duty
$39PliersAdd to cartDescriptionThis punch plier is ideal for making holes on watchband, belts, gaskets, leather, canvas, textiles and soft materials.SpecificationMaterial:SteelColor:BlackLength:25cm (9.8inch) approx.Hole size:4.5mm, 4mm, 3.5mm, 3mm, 2.5mm, 2mmFeatures1. Ideal for making holes on watchband, belts, gaskets, leather, canvas, textiles and soft materials.2. Ergonomical rubber handle and anti-slip grip allow you comfortably punching over long time.3. Revolving head …
Punch Plier Leather Belt Round Hole Punch Eyelet Strap Revolving DIY Tool Heavy DutyRead More
-
WT3220 infrared thermal Imager 220*160 infrared Image Resolution 2.8inch Color Screen Digital Display Professional Handheld HD IR thermal Imager
$779Thermal ImagerAdd to cartFeatures– Dual Function:Combine the functions of surface temperature measurement and real-time thermal imaging. – Time Saving:No need to measure each component one by one anymore, saving your time.– High-definition Images:With the 2.8′ full color display screen, this thermal camera can help you observe the full range of infrared images.– Image Overlapping:Image overlapping makes it easier …
-
DANIU Transparent Practice Padlock with 12pcs Unlocking Lock Picks Set Key Extractor Tools
$22Picks and Padlocks SetAdd to cartDescriptionTransparent Practice Padlocks with 12pcs Unlocking Lock Pick Set Key Extractor Tool Lock Pick ToolsYou can see clearly that how the pins work when a key is inserted.It will come out in perfect smooth working condition with no loose parts or pins.Lock with open chambers on all the moving parts that allow you to see …
DANIU Transparent Practice Padlock with 12pcs Unlocking Lock Picks Set Key Extractor ToolsRead More
Reviews
There are no reviews yet.